Glass and orientation carry the load
A west-facing living room with full-height windows can need substantially more capacity than a north-facing bedroom of the same size. The afternoon sun lands on that glass and the room stores the heat in its walls and floor, which is why it stays warm long after the sun has moved off.
A floor-area rule ignores all of it. Applied honestly, it usually sizes the room for an average day and leaves the owner disappointed in February.
Oversizing is a real mistake
An oversized unit cools the air quickly and then cycles off, removing less moisture than the room needs. The result feels cold and clammy, the compressor starts and stops constantly, and the equipment wears faster than a correctly sized unit running steadily.
Correct capacity with sensible zoning beats raw kilowatts every time, particularly in open-plan living areas.
What the survey should establish
Orientation, glass area, shading, ceiling height and insulation are the physical inputs. Occupancy and how the room is used are the practical ones: a home office with two people and a server runs differently from a guest bedroom.
Add the electrical supply and the plant position to that list. A perfect capacity calculation on a board with no spare way is still an unfinished job.